Please ensure Javascript is enabled for purposes of website accessibility

CHAPTER 16-09

SEWAGE DISPOSAL SECTIONS:

16-0901. Requirements.

16-0902. Size of Service.

16-0903. Service Connection Standards.

_________________________

16-0901. REQUIREMENTS. The entire sewage system shall be connected to the City Sewage System at a location approved by the City Engineer. The system shall comply in every way with the City and State Plumbing Codes.

16-0902. SIZE OF SERVICE. A minimum of four (4") inch service shall be provided to each mobile home stand and collection lines shall be approximately sized to handle the normal flow plus a safety factor of two and one-half (2½).

16-0903. SERVICE CONNECTION STANDARDS. Any surface sewage connection, including, but not limited to, mobile home drain connections, shall be of hubless cast iron soil pipe or schedule 40 PVC or ABS plastic pipe not less than four (4) inches in size and not less than three (3) inches inside diameter. Drain Connections shall be gas and water tight. Each service to any surface sewage connection, including, but not limited to, mobile home drain connections, not in use shall be equipped with a hubless sewer plug.